Ma 8.1 - Bcl - Connecting The Bcl 8 To The Ma 8.1; Figure 5.1: Ma 8.1 - Pin Assignment Bcl - Leuze electronic BCL 8 Series Original Operating Instructions

Bar code reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

5.2.4

MA 8.1 - BCL - connecting the BCL 8 to the MA 8.1

RXD
SWIN/SWOUT
GND
M12 socket
Figure 5.1:
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
The BCL 8 is connected to the MA 8.1 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the PWR IN HOST/RS232 socket.
ATTENTION!
It is absolutely necessary to connect the functional earth, since all electrical interference
(EMC coupling) is discharged via the functional earth connection.
Leuze electronic
BCL (5-pin socket, A-coded)
Pin
VIN
4
1
1
5
2
3
2
TXD
3
4
BCL 8
5
Thread
MA 8.1 - Pin assignment BCL
Name
Supply voltage for BCL 8
VIN
+4.9 ... +5.4VDC
TXD
RS 232 transmission line
GND
Supply voltage: 0VDC
RXD
RS 232 receiving line
SWIN/
Programmable switching input/output of the
SWOUT
BCL 8
FE
Functional earth (housing)
BCL 8
Accessories/order codes