(4) Modification of the source voltage specifications

A changeover setting can be made only for the control box conforming to the specifications of single-phase 100
to120V / 3-phase 200 to 240V.
For the source voltage changeover setting, change the changeover terminal connections according to 2)
Replacement of boards 3. FTL board asm.
Power cord connections are made as described below.
When a single-phase 100 to 120V power supply is used, make power code plug connections such that the wires
of Black and White are connected to the AC power and the wire of green/yellow is connected to the earth
system.
In single-phase operation, the wire of Red need not be connected. Both ends should be cut off at the root of the
cord.
When a 3-phase AC 200 ~ 240V power supply is used, make power code plug connections such that the wires
of Black, White, and Red are connected to the AC power and the wire of green/yellow is connected to the earth
system.
Wiring for single-phase 100 to 120V specifications
AC100 to 120
AC100 to 120
FG
Wiring for 3-phase AC 200 to 240V specifications
AC200 to 240
AC200 to 240
AC200 to 240
FG
Plug
Black
White
Green/
yellow
Plug
Black
White
Red
Green/
yellow
Power cord
Both ends cut off for Red
Power cord
– 144 –
Power switch
Power switch