Adjustment The Bobbin Thread Remaining Amount Detection - JUKI APW-895 Engineer's Manual

Lockstitch, automatic welting machine, parallel pocket with flap sewing
Table of Contents

Advertisement

19) Adjustment of the bobbin thread remaining amount detection
1.Sensor lateral direction
2.Adjustment of the sensor lateral direction
3.Method of sensor check
Standard Adjustment
Sensor indicator:
OFF stability display: Lit in green (Orange unlit)
ON stability display: Lit in green and orange (Both unlit or
lighting in orange only indicates an unstable condition.)
Groove section
– 25 –
A
B

Advertisement