Adjustment Procedures
12. Adjustment of clamp base position
(1) Adjust the clamp base position to set the distance between the clamp
base and stacker base E
(2) Loosen the cylinder rod fixing nut
cylinder rod
, and move the rod in the arrow direction to make
adjustment.
*
The goal dimension is 369mm in the state that the cylinder rod
protruded.
13. Adjustment of second clamp bar position
(1) Adjust the 2nd clamp bar position to set the distance between the
clamp bar and stacker base E
20 ± 2.5 mm in the X-axis.
(2) Loosen the 2nd clamp bar drive cylinder rod fixing nut
2nd clamp bar drive cylinder rod
direction to make adjustment.
*
The goal dimension is 367mm in the state that the cylinder rod
protruded.
to 83 ± 2.5 mm and 167 ± 2.5mm.
, rotate the 2nd clamp bar drive
to 105 ± 2.5 mm in the Y-axis and
, and move the rod in the arrow
– 90 –
Results of Improper Adjustment
is
, rotate the
is

Advertisement