Memory Switch Data List - JUKI APW-895 Engineer's Manual

Lockstitch, automatic welting machine, parallel pocket with flap sewing
Table of Contents

Advertisement

(3) Memory switch data list

• Level 1
Memory switch data (level 1) are the motion data the sewing machine has in common and the data that operate on
all sewing patterns in common.
No.
Change-over of the position of clamp foot after sewing end
Position of clamp foot after sewing end is selected from Stop at front end/
Return to medium/Clamp return/Stop at rear end.
Front end motion start waiting time
Waiting time up to the start of front end motion of clamp foot is set.
* It is possible to set only when
Number of times of feeding of automatic interlining supplying at sewing start
Number of times of feeding of automatic interlining supplying device at
sewing start is set.
* It is possible to set only when
option is used.
Feeding length of automatic interlining supplying at sewing end
Feeding length of automatic interlining supplying device at sewing end is set.
* It is possible to set only when
device is used.
Thread trimming timing
Thread trimming timing after sewing is selected from Standard/ Medium/
Longest and length of thread at sewing end is adjusted
* When
thread may not be trimmed.
Stacker timer 2
Waiting time from the start of clamp motion to hold material on the stacker
base to release the material presser is set.
* It is possible to set only when
......... Item that is not displayed due to other setting start.
Item
Stop at front end
Clamp return
is set to the stop at front end.
automatic interlining supplying
automatic interlining supplying
Standard 0
Longest 2
and
zipper device are mounted setting is "0", needle
clamp bar stacker option is used.
Return to medium
Stop at rear end
Medium 1
– 99 –
Setting range
/
Initial value
Edit unit
- - -
- - -
0.00 to 9.99
3.00 sec.
/
0.01 sec.
2 to 9
3
/
1
0 to 99.9
0mm
/
0.1mm
- - -
0.00 to 9.99
0.70 sec.
/
0.01 sec.

Advertisement