JUKI APW-895 Engineer's Manual page 108

Lockstitch, automatic welting machine, parallel pocket with flap sewing
Table of Contents

Advertisement

• Level 2
Memory switch data (level 2) are the motion data that the sewing machine has in common and the data that
operate on all sewing patterns in common. The data are for the maintenance personnel and possible to edit by
pressing the mode switch as long as 6 seconds.
No.
Marking light mounting
Mounting/Non-mounting of marking light is selected. When "Non mounting" is
selected, marking light does not work.
Sewing position selection
Mode that surely ends sewing at rear reference position, mode that surely
starts sewing from front reference position or the conventional motion mode
that changes sewing position according to the setting of
* Front reference position: 80mm from needle
Rear reference position : 300mm from needle
(Long type : 330mm)
Setting of solenoid valve for corner knife separate drive
Mounting/non mounting of solenoid valve corner knife separate drive is set.
Pedal operation mode change-over
Mode to be used for foot pedal is set.
Excess rate of center knife cutting
Excess rate in terns of the speed of revolution of center knife can be set.
Setting on intermittent feed prohibition
Perform/not perform intermittent feed sewing is selected.
* When performing intermittent sewing, the max. sewing speed of sewing
machine is limited 1, 500 rpm.
Item
Non mounting
Conventional
motion mode
Sewing position fixed
mode (Front reference)
Non mounting
7-step pedal mode
Perform intermittent
feed sewing
Mounting
is selected.
Sewing position fixed
mode (Rear reference)
Mounting
1-shot pedal mode
Not perform intermittent
feed sewing
– 103 –
Setting range
/
Initial value
Edit unit
- - -
- - -
- - -
- - -
300 to 500
350%
/
1%
- - -

Advertisement

Table of Contents
loading