Memory Switch Data List; Data List - JUKI AMS-210EN-7450 Instruction Manual

Hide thumbs Also See for AMS-210EN-7450:
Table of Contents

Advertisement

3. MEMORY SWITCH DATA LIST

Memory switch data are the motion data that the sewing machine has in common and the data that op-
erate on all sewing patterns in common.

3-1. Data list

No.
Maximum sewing speed
Sewing speed of 1st stitch
In case of with thread clamp
Sewing speed of 2nd stitch
In case of with thread clamp
Sewing speed of 3rd stitch
In case of with thread clamp
Sewing speed of 4th stitch
In case of with thread clamp
Sewing speed of 5th stitch
In case of with thread clamp
Thread tension of 1st stitch
In case of with thread clamp
Thread tension setting at the time
of thread trimming
Thread tension changeover
timing at the time of thread trimming
Sewing speed of 1st stitch
In case of without thread clamp
Sewing speed of 2nd stitch
In case of without thread clamp
Sewing speed of 3rd stitch
In case of without thread clamp
Sewing speed of 4th stitch
In case of without thread clamp
Sewing speed of 5th stitch
In case of without thread clamp
Thread tension of 1st stitch
In case of without thread clamp
Thread tension changeover timing
at the time of sewing start
In case of without thread clamp
Item
– 12 –
Setting range
Edit unit
200 to 2000
100 sti/min
200 to 900
100 sti/min
200 to 2000
100 sti/min
200 to 2000
100 sti/min
200 to 2000
100 sti/min
200 to 2000
100 sti/min
0 to 200
1
0 to 200
1
– 6 to 6
1
200 to 1500
100 sti/min
200 to 2000
100 sti/min
200 to 2000
100 sti/min
200 to 2000
100 sti/min
200 to 2000
100 sti/min
0 to 200
1
– 5 to 2
1

Advertisement