21. Method of changing memory switch data

1) Set the mode to input mode.
Under the input mode where SET READY LED
 goes out, change to the memory switch data is
enabled.
If the current mode is the sewing mode, press
READY key ❷
to the input mode.
2) Call memory switch data edit screen.
When MODE key ❹
mode screen (operator level) is displayed.
On this screen, select the memory switch data
(level 1).
When MODE key ❹
three seconds, the mode screen (maintenance
personnel level) is displayed.
On this screen, the memory switch data (level 2)
can be selected.
3) Select memory switch data to change.
Press ITEM SELECT key ❻
4) Change data.
There are one data item to change the numerical value and the other data item to select the pictograph in
the memory switch data.
No. such as
is attached to the data item to change the numerical value. Set value can be changed
by increasing/decreasing the value with DATA CHANGE key ❼
No. such as
is attached to the data item to select the pictograph. Pictograph can be selected with
DATA CHANGE key ❼
→ For the details of memory switch data, refer to
to change over the mode
is pressed, the
is held pressed for
and select the data item which you desire to change.
.