Installation
Install the
the Control
Control Module
Install
Install
the
Control
1. Shut off and lock out power to the motor.
2. Assemble the bracket kit (6a-6f) and the holder
and tie (11, 12) as shown.
3. Install the module (1) in the bracket (6a), making
sure the tabs at the bottom of the bracket engage
the slots in the module, and the lip at the top of
the bracket holds the module securely in place.
Figure 4 Install the Control Module
Figure 5 Connect the Control Module
10
Module
Module
Connect the
the Control
Control Module
Connect
Connect
the
Control
1. If still on, shut off and lock out power to the motor.
2. Connect the gray end of the accessory cable (25)
into port 3 on the bottom of the control module.
Use the tie (12) as a strain relief. Connect the
red end of the accessory cable (25) into power
terminal (PT) 1 on the first motor.
3. Plug the gray end of the second accessory cable
(25) into PT 2 on the first motor and the red end
of the accessory cable (25) into PT 1 on motor 2.
4. Install the jumper connector (5) over PT 2 and
PT 3 on motor 2, using the screw (5a).
5. Restore power to the motor.