Graco E-Flo DC Series Instructions Manual page 61

Circulation pumps
Hide thumbs Also See for E-Flo DC Series:
Table of Contents

Advertisement

Modbus
Modbus
Modbus
Variable
Variable
Variable
Register
Register
Register
404119
Run/Stop Switch State
Extended Modbus Variables
The registers shown in this section are intended for advanced integration solutions, where the user desires full
control of the system by the PLC. For optimal communication latency, it is recommended that only the registers
which will be monitored and changed on a regular basis be mapped and the remaining parameters be configured
with the display.
404150
Pressure Minimum
404151
Pressure Target
404152
Pressure Maximum
404153
Flow Minimum
404154
Flow Target
404155
Flow Maximum
404156
Mode
404157
BPR % Open
404158
Pressure/Force Min Alarm Type
404159
Pressure/Force Max Alarm Type
404160
Flow Min Alarm Type
404161
Flow Max Alarm Type
3A3453H
Appendix A - Modbus Variable Map
Register
Register
Register
Size
Size
Size
Access
Access
Access
16 Bit
Read Only
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
16 Bit
Read Only
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Notes/Units
Notes/Units
Notes/Units
0 = Switch closed (Stop state),
1 = Switch open (Run state)
Pressure units, see Table 7.
Pressure units, see Table 7.
Pressure units, see Table 7.
Flow units, see Table 7.
Flow units, see Table 7.
Flow units, see Table 7.
0 = pressure,
1 = flow
Value will be 0-100
(Approximately 1-100 psi, see
manual 332142 for information
on BPR control kit)
0 = limit, 1 = deviation, 2 = alarm
0 = limit, 1 = deviation, 2 = alarm
0 = limit, 1 = deviation, 2 = alarm
0 = limit, 1 = deviation, 2 = alarm
61