404114 - - - Display
Display Events
Events — — — High
404114
404114
Display
Events
Bit
Event Type
0
Deviation
1
Alarm
2
Deviation
3
Alarm
4
Deviation
5
Alarm
6
Deviation
7
Alarm
Others
404115
404115 - - - Display
404115
Display
Display Events
Events — — — Low
Events
Bit
Event Type
0
Alarm
1
Deviation
2
Deviation
3
Deviation
4
Alarm
5
Deviation
6
Advisory
7
Deviation
8
Alarm
9
Deviation
10
Alarm
11
Deviation
12
Alarm
13
Deviation
14
Alarm
15
Alarm
3A3453H
High Word
Word
High
Word
Event Code
P6CX
L1AF
P3CB
P4CB
P2CB
P1CB
P7CX
P9CX
Low
Low Word
Word
Word
Event Code
P5D_
P1D_
CAG_
C3GX
C4GX
P9D_
EBCX
L3AO
L4AO
L2AO
L1AO
F2FO
F1FO
L6CA
L6CB
CACX
Appendix A - Modbus Variable Map
Event Name
Pressure Transducer Error
Primary Tank Freeze Alarm
Pressure Transducer 2 High Deviation
Pressure Transducer 2 High Alarm
Pressure Transducer 2 Low Deviation
Pressure Transducer 2 Low Alarm
Pressure Delta Deviation
Pressure Delta Alarm
Reserved
Event Name
Transducer Assignment Conflict
Unbalanced Load
Solenoid Keep Alive Signal Not Detected
Modbus Communications Lost
Modbus Communications Lost
Major Unbalanced Load (x2 System)
Run/Stop Switch Closed
Primary Tank High Deviation
Primary Tank High Alarm
Primary Tank Low Deviation
Primary Tank Low Alarm
No Flow Fill Pump Deviation
No Flow Fill Pump Alarm
Port 8 4 to 20 mA open circuit
Port 9 4 to 20 mA open circuit
Display CAN Communication Alarm
69