Graco E-Flo DC Series Instructions Manual page 47

Circulation pumps
Hide thumbs Also See for E-Flo DC Series:
Table of Contents

Advertisement

Display
Display
Display
Applicable
Applicable
Applicable
Code
Code
Code
Motor
Motor
Motor
EBC_
Advanced
EBC_
EBC_
ELI_
ELI_
ELI_
Basic and
Advanced
ERR0_
Basic and
ERR0_
ERR0_
Advanced
F1F0
F1F0
F1F0
F2F0
F2F0
F2F0
K1D_
K1D_
K1D_
Advanced
K2D_
K2D_
K2D_
Advanced
K3D_
K3D_
K3D_
Advanced
K4D_
K4D_
K4D_
Basic and
Advanced
L1A0
L1A0
L1A0
L1AF
L1AF
L1AF
Advanced
L2A0
L2A0
L2A0
Advanced
L3A0
L3A0
L3A0
Advanced
L4A0
L4A0
L4A0
L6CA
L6CA
L6CA
L6CB
L6CB
L6CB
MND_
MND_
MND_
Advanced
P1CB
P1CB
P1CB
Advanced
P1D_
Advanced
P1D_
P1D_
P9D_
Advanced
P9D_
P9D_
P1I_
Advanced
P1I_
P1I_
P2I_
P2I_
P2I_
Advanced
P2CB
P2CB
P2CB
Advanced
P3CB
P3CB
P3CB
Advanced
P3I_
P3I_
P3I_
Advanced
P4CB
P4CB
P4CB
Advanced
P4I_
P4I_
P4I_
Advanced
3A3453H
Blink
Blink
Blink
Alarm
Alarm or or or
Alarm
Code
Code
Code
Deviation
Deviation
Deviation
None
Advisory Run/Stop switch in Stop position (closed).
4–5
Deviation Deviation hot board reset.
2–5
Deviation Deviation software error.
None
Alarm
Fill pump flow not detected. The primary tank level has not
increased with the no flow timeout window and the no flow
timeout event is set to alarm.
None
Deviation Fill pump flow not detected. The primary tank level has not
increased with the no flow timeout window and the no flow
timeout event is set to deviation.
1–2
Alarm
Flow is below minimum limit.
None
Deviation Flow is below minimum limit.
None
Deviation Flow exceeds maximum target; also indicates pump runaway
condition exists.
1
Alarm
Flow exceeds maximum target; also indicates pump runaway
condition exists.
None
Alarm
The flow rate is above the current profile flow limit set on Profile
Screen 3.
None
Alarm
While the system was in off production mode, the current tank
level dropped 3% below the value that was recorded when the
pump entered off production.
None
Deviation The primary tank current level is below the primary tank deviation
set point.
None
Deviation The primary tank current level is above the primary tank deviation
set point.
None
Alarm
The primary tank level is above the primary tank level high alarm
set point.
None
Deviation Port 8 is enabled and the current draw is less than 4 mA. The
BPR is requesting a value greater than 0%. Verify that the device
is connected.
None
Deviation Port 9 is enabled and the current draw is less than 4 mA. Verify
that the device is connected.
None
Advisory Maintenance counter is enabled and countdown reached zero
(0).
None
Alarm
Pressure transducer 2 pressure is below the alarm set point.
None
Deviation Unbalanced load. Dual Lower system — P1D1 = Motor 1 is
requiring less force to hold speed; pump lower may need service.
P1D2 = Motor 2 is requiring less force than motor 1 to hold speed.
None
Deviation Major unbalanced load — see P1D_ (P9D_ is higher magnitude)
1–3
Alarm
Pressure is below minimum limit.
None
Deviation Pressure is below minimum limit.
None
Deviation Pressure transducer 2 pressure is below the deviation set point.
None
Deviation Pressure transducer 2 pressure is above the deviation set point.
None
Deviation Pressure exceeds maximum target.
None
Alarm
Pressure transducer 2 pressure is above the alarm set point.
1–4
Alarm
Pressure exceeds maximum target.
Error Code Troubleshooting
Description
Description
Description
47