Appendix A - Modbus Variable Map - Graco E-Flo DC Series Instructions Manual

Circulation pumps
Hide thumbs Also See for E-Flo DC Series:
Table of Contents

Advertisement

Appendix A - Modbus Variable Map

Appendix A A A - - - Modbus
Appendix
Appendix
To communicate through fiber optics with the E-Flo
DC Control Module, reference the appropriate
hardware as shown in manual 332356. That
manual indicates various options for connecting
fiber optic cables from the control module to the
non-hazardous area. The following table lists
Modbus registers available to a PC or PLC located in
the non-hazardous area.
Table
Table
Table 5 5 5 Modbus
Modbus
Modbus Registers
Registers
Registers
Modbus
Variable
Modbus
Modbus
Variable
Variable
Register
Register
Register
403225
Fill Pump Solenoid Out
403226
Solenoid Out Keep Alive
403227
Reed Switch Count
403228
Tank Level 1 Full Pressure
403229
Tank Level 2 Full Pressure
403230
Actual Tank Level 1%
403231
Actual Tank Level 2%
403232
Configurable IO Type
403233
Agitator Half Status
403234
Accessory Solenoid Out
404100
Pump Status Bits
404101
Actual Pump Speed
404102
Actual Pump Flow Rate
404103
Actual Pump Pressure
404104
Transducer 1 Pressure
404105
Transducer 2 Pressure
404106
Batch Total High Word
404107
Batch Total Low Word
404108
Grand Total High Word
404109
Grand Total Low Word
404110
Maintenance Total High Word
404111
Maintenance Total Low Word
404112
Pump Events 1 — High Word
404113
Pump Events 1 — Low Word
404114
Display Events — High Word
404115
Display Events — Low Word
404116
Pump Events 2 — High Word
404117
Pump Events 2 — Low Word
404118
System Type
60
Modbus Variable
Variable Map
Modbus
Variable
Map
Map
Table 4 shows the registers needed for basic
operation, monitoring, and alarm control features.
Tables 5 and 6 provide bit definitions as needed for
certain registers. Table 7 shows the units and how to
convert the register value to a unit value.
Reference the Modbus communication settings
selected in
Setup Screen 16, page
Register
Register
Register
Size
Size
Size
Access
Access
Access
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read/Write
16 Bit
Read Only
16 Bit
16 Bit
Read Only
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
16 Bit
Read Only
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
Read Only
16 Bit
16 Bit
Read Only
Read Only
16 Bit
16 Bit
Read Only
Read Only
16 Bit
41.
Notes/Units
Notes/Units
Notes/Units
0 = Off, 1 = On
Write any value to activate.
Cycle count
Pressure units, see Table 7.
Pressure units, see Table 7.
Pressure units, see Table 7.
Pressure units, see Table 7.
0 = Reed switch input,
1 = Drum cover switch input
0 = Drum cover down,
1 = Drum cover up,
2 = Accessory solenoid out
0 = Off, 1 = On
See Table 6 for bit definitions.
Speed units, see Table 7.
Flow units, see Table 7.
Percent pressure, see Table 7.
Pressure units, see Table 7.
Pressure units, see Table 7.
Volume units, see Table 7.
Volume units, see Table 7.
Pump cycles, see Table 7.
Pump cycles, see Table 7.
Pump cycles, see Table 7.
Pump cycles, see Table 7.
See Table 5 for bit definitions.
See Table 5 for bit definitions.
See Table 5 for bit definitions.
See Table 5 for bit definitions.
See Table 5 for bit definitions.
See Table 5 for bit definitions.
0 = Single lower,
1 = Dual lower
3A3453H