Operation
Setup
Setup Screen
Setup
Screen 14
Screen
14
14
Use this screen to monitor, set up, and control
the Intelligent Paint Kitchen peripherals. For more
information, see the Set Up Peripherals section of
the Intelligent Paint Kitchen manual 3A4030.
NOTE:
NOTE:
NOTE: The second field varies, depending on the
menu selection in the first field.
Select the connected peripheral from the menu.
Allows for the connected device to receive an alarm when the level of the primary tank is above the
value that is defined in this field. If the value is set to 0, the event is disabled.
Allows for the connected device to receive an alarm when the level of the primary tank is below the value
that is defined in this field. If the value is set to 0, the event is disabled.
An event can be configured as a deviation or an alarm. In the event of an alarm, the pump shuts
off and the agitator turns off.
40
Configures Port 4 pin 4 as an input to allow a reed switch to be connected.
The current reed switch cycle rate appears next to the cycle rate icon
minute.
Configures Port 4 pin 4 as an input to allow a pressure switch to be connected. If the drum
cover is lifted while this configuration is properly connected, the agitator shuts down.
The current input status appears in the agitator status field
NOTE: A Supervisor Module is required for this function.
Configures Port 4 pin 4 as an output to allow for the connected device to receive an alarm
when the level of the Primary Tank is above the value that is defined in the Primary Tank
High field
This value is a percentage of the total level of the Primary Tank.
Configures Port 4 pin 4 as an output to allow for the connected device to receive an alarm
when the level of the Primary Tank is below the value that is defined in the Primary Tank
Low field
This value is a percentage of the total level of the Primary Tank
Configures Port 4 pin 4 as an output to allow for another solenoid to be connected and
controlled from the device.
Select the manual output box
solenoid manually. After you release the button, the manual activation is terminated.
Figure 50 Setup Screen 14
Setup Screen
Screen 14
14 Key
Key
Setup
Setup
Screen
14
Key
.
.
and hold the button to control the auxiliary
in cycles per
.
3A3453H