Graco E-Flo DC Series Instructions Manual page 64

Circulation pumps
Hide thumbs Also See for E-Flo DC Series:
Table of Contents

Advertisement

Appendix A - Modbus Variable Map
Modbus
Variable
Modbus
Modbus
Variable
Variable
Register
Register
Register
Intelligent Paint Kitchen Registers
Setup
406129
Pump 1 Alarms High Word
406130
Pump 1 Alarms Low Word
406131
Display 1 Alarms High Word
406132
Display 1 Alarms Low Word
406133
Pump 1 Alarms 2 High Word
406134
Pump 1 Alarms 2 Low Word
406135
Pump 2 Alarms High Word
406136
Pump 2 Alarms Low Word
406137
Pump 2 Alarms 2 High Word
406138
Pump 2 Alarms 2 Low Word
406139
Pump Control Bitfield
406140
Configuration
406141
System Type
406142
Pressure Units
406143
Volume Units
406144
Flow Units
406145
Agitator Speed Units
406146
Stop Profile BPR % Setting
406147
Primary Tank Level High Alarm
406148
Primary Tank Fill Target
406149
Primary Tank Fill Level
406150
Primary Tank Level Low Alarm
406151
Primary Tank Freeze Level Alarm
406152
TBD
64
Register
Size
Register
Register
Size
Size
Access
Access
Access
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Notes/Units
Notes/Units
Notes/Units
bit 0 = Clear Alarm
bit 1 = Reset Batch
bit 2 = Reset Maint Counter 1
bit 3 = Reset Maint Counter 2
bit 4 = Reset Maint Agitator
bit 0:
0 = Local
1 = Remote
bit 14: Run/Stop Switch
0 = Disable
1 = Enable
bit 15: Remote Start
0 = Enable
1 = Disable
0 = Single Lower
1 = Dual Lower
0 = Psi
1 = bar
2 = Mpa
0 = Liters
1 = Gallons
0 = Liter/min
1 = Gallons/min
2 = cc/min
3 = oz/min
4 = Cycles / min
0 = Percent
1 = Hertz
2 = RPM
0-100
0-100
0-100
0-100
0-100
0-65535
0-65535
3A3453H