Graco E-Flo DC Series Instructions Manual page 38

Circulation pumps
Hide thumbs Also See for E-Flo DC Series:
Table of Contents

Advertisement

Operation
Setup Screen
Setup
Setup
Screen 11
Screen
11
11
This screen is auto-populated with the serial numbers
and software versions for each motor.
In this system there is a parent motor and a child
motor. The parent motor controls itself to the active
profile setpoints while the child follows. The first
serial number listed on this screen corresponds to
the parent and the second to the child.
NOTE: These serial numbers match the name plates
NOTE:
NOTE:
attached to the side of the motor.
Each motor can be run individually by disabling the
other (X in the selection box).
Figure 44 Setup Screens 11
38
Setup
Setup Screen
Setup
Screen 12
Screen
12
12
Use this screen to set your modbus preferences.
Figure 45 Setup Screen 12
Setup Screen
Screen 12
Setup
Setup
Screen
Control location. Select local
remote
options. Setting applies to the selected
pump only.
Enter or change the Modbus node ID.
Value is between 1 and 247. Each
pump requires a unique node ID, which
identifies that pump if more than one
pump is connected to the display.
Select serial port baud rate from the
dropdown options: 38400, 57600, or
115200. This is a system-wide setting.
Figure 46 Select Local or Remote Control
Figure 47 Set Modbus Node ID
Figure 48 Set Baud Rate (Bits Per Second)
NOTE:
NOTE: The following are fixed modbus settings,
NOTE:
which cannot be set or changed by the user: 8 data
bits, 2 stop bits, no parity.
12 Key
Key
12
Key
or
control from the dropdown
3A3453H

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-flo dc 2000E-flo dc 3000E-flo dc 4000

Table of Contents