Repair
8. Models
Models with
Models
with Sealed
with
Sealed Lowers:
Sealed
(10) by engaging the bottom lips with the groove
in the top plate. Snap the two shields together.
9. Remove the plugs and reconnect the inlet and
outlet manifolds (3).
10. Flush and test the pump before reinstalling
it in the system. Connect hoses and flush
the pump. While it is pressurized, check for
smooth operation and leaks. Adjust or repair
as necessary before reinstalling in the system.
Reconnect the pump ground wire before
operating.
Figure 64 Reassembly with Open Wet Cup Lower