Troubleshooting

Troubleshooting
Troubleshooting
NOTE:
NOTE: Check all possible remedies before disassembling the pump.
NOTE:
NOTE: The LED on the motor will blink if an error is detected. See Error
NOTE:
NOTE:
manual for further information.
Problem
Problem
Problem
Pump output low on both strokes.
Pump output low on only one stroke.
No output.
Pump operates erratically.
Pump will not operate.
3A3453H
Cause
Cause
Cause
Inadequate power supply.
Exhausted fluid supply.
Clogged fluid outlet line, valves, etc.
Worn piston packing.
Held open or worn ball check valves. Check and repair. See lower manual.
Worn piston packing.
Improperly installed ball check
valves.
Exhausted fluid supply.
Held open or worn ball check valves. Check and repair. See lower manual.
Worn piston packing.
Inadequate power supply.
Exhausted fluid supply.
Clogged fluid outlet line, valves, etc.
Fluid dried on piston rod.
Error Code
Code Troubleshooting
Troubleshooting in the motor
Error
Code
Troubleshooting
Solution
Solution
Solution
See
Power Supply Requirements,
page
11.
Refill and reprime pump.
Clear.
Replace. See lower manual.
Replace. See lower manual.
Check and repair. See lower manual.
Refill and reprime pump.
Replace. See lower manual.
See
Power Supply Requirements,
page
11.
Refill and reprime pump.
Clear.
Disassemble and clean pump. See
lower manual. In future, stop pump
at bottom of stroke.
Troubleshooting
45