2.3 Power Supply Troubleshooting
Procedure 2
Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN LED blinks orange. The
blink pattern indicates an error as shown below.
! Start
! Error code (8 bit)
"1"
"0"
Interval between data bits
The error code begins with the least significant digit.
Example: Error code 12h (Error codes are given in hexadecimal format.)
ON
OFF
Satellite 1400/2400 Series Maintenance Manual (960-364/365)
Off for 2 seconds
On for one second
On for a half second
Off for a half second
0
1
Start
Bit 0
1
Order
2 Troubleshooting Procedures
Read
0
0
1
0
0
2
3
4
5
6
0
7
2-9