FLOOR SENSOR

When reinstalling Floor Sensor or if the Floor Sensor does not function properly, refer to the following adjustment
method to make corrections.
Floor Sensors Green LED and Yellow LED show the operating state.
1
Floor sensor is composed of two items: Refl ector, sensor
Adjust part
of the picture below when adjustment is needed.
A
A
2
Remove 4 M5 X 12 truss screws from the fl oor sensor cover
(Floor sensors have different shapes. But adjustment and assembling are the same.)
Floor Sensor Cover
Truss Screw(4)
M5 X 12
FIG. 14a