PROBLEMS
Access failure to
MOTION CONTROL
BD TEST MODE
SEAT does not operate
Some of the items
on the input test of
the GAME BDTEST
MODE are not
selectable.
Network play does not
work.
CAUSE
Game is running.
Cabinet movement is set at
OFF in the game assignment
of the test mode.
LINK ID setting is not proper.
Seat does not initialize.
FLOOR SENSOR is blocked.
FLOOR SENSOR beam is not
targeted at the center of the
mirror.
SEATBELT is not fastened
MOTION STOP BUTTON is
pressed.
MOTOR / DRIVE BD
malfunction.
Communications check
between GAME BD and
MOTION CONTROL BD is
not complete.
Bad network settings
LAN cable is not connected
Damaged LAN cable
COUNTERMEASURES
Retry when ADVERTISE screen is on.
Change the setting to ON.
Adjust the link ID settings
Shut down the power to the machine and re-
connect the power. Restart the initialization.
Remove all obstacles.
Adjust the SENSOR.
Lock the SEATBELT.
End the game.
Check the function in the MOTION TEST.
Complete the communications check.
Adjust settings
Check the connections
Replace cables