Leds For The Status Display Of The Valve Solenoid Coils - Festo CPV-DI01 Manual

Hide thumbs Also See for CPV-DI01:
Table of Contents

Advertisement

7. Diagnosis with the ABB CS31

7.1.3 LEDs for the status display of the valve solenoid coils

LED
Colour
out
yellow
lights up
Fig. 7/5: LEDs for the status display of the valve solenoid coils
7-6
There is a yellow LED for each valve solenoid coil (see
Fig. 7/1). This LED indicates the switching status of the valve
solenoid coil.
Switch position
valve solenoid coil
Basic position
– switch position
or
– basic position
Please note
If there is no valve coil, the assigned LED will not indicate
control of the output.
Error treatment
logical 0 (no signal)
logical 1 (signal present)
logical 1 but:
– load voltage of the valves lies
below the permitted tolerance
range ( < 20.4V DC)
or
– compressed air supply not
correct.
or
– pilot exhaust blocked
or
– servicing required
Festo P.BE-CP-DI01-EN en 0007a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpv di01 series

Table of Contents