Festo CPV-DI01 Manual page 45

Hide thumbs Also See for CPV-DI01:
Table of Contents

Advertisement

1. Installation
Total current consumption The following table shows you how to calculate the total cur-
Festo P.BE-CP-DI01-EN en 0007a
rent consumption of a CP system. The values specified have
been rounded up.
Current consumption for the CP
electronics (pin 1)
CPV Direct
max. 100 mA
CPV valve terminal
max. 40 mA
CPA valve terminal
20 mA
CP input module
max. 40 mA
Sensors
See manufacturer
specifications
CP output module
max. 40 mA
Carried forward
Current consumption of the valve supply (pin 2)
Current consumption
of all simultaneously
1)
energized valve coils
__ x ____ mA
1)
Current consumption depends on valve type (see Technical
specifications of the valves)
Sums
= ______ mA
= ______ mA
1-31