8. Commissioning the Moeller SUCOnet K
8.1.2 Address assignment of the CPV valve terminal
8-4
The CPV valve terminal with field bus direct connection al-
ways occupies 16 output addresses, irrespective of the
number of valve coils fitted on it. This enables the CPV valve
terminal to be extended at a later stage without the need to
shift the addresses.
The diagram below shows the addressing sequence of the
individual CPV valve plates.
4-5
8-9
0-1
2-3
6-7
10-11
Fig. 8/1: Address assignment of a CPV valve terminal
–
A valve location on the CPV valve terminal always oc-
cupies 2 addresses, even if it is fitted with a reserve plate
or pressure isolation plate. If a valve location is fitted with
a double-solenoid valve, the following allocation applies:
–
pilot solenoid 14 occupies the lower-value address,
–
pilot solenoid 12 occupies the higher-value address.
The higher-value address remains unused with single-
solenoid valves.
12-13
14-15
Festo P.BE-CP-DI01-EN en 0007a