6 To Make Measurements
Voltage Parameters
Vmax
Vtop
Vpp
Vbase
Vmin
1. Vmax: the voltage value from the highest point of the waveform to the GND.
2. Vmin: the voltage value from the lowest point of the waveform to the GND.
3. Vpp: the voltage value from the highest point to the lowest point of the
waveform.
4. Vtop: the voltage value from the flat top of the waveform to the GND.
5. Vbase: the voltage value from the flat base of the waveform to the GND.
6. Vamp: the voltage value from the top of the waveform to the base of the
waveform.
7. Vavg: the arithmetic average value of the whole waveform or the waveform in
the gating area.
=
Average
n
measured, n is the number of points being measured.
8. Vrms-N: the root mean square value of the whole waveform or the waveform in
the gating area.
n
2
x
i
=
i
1
=
RMS
n
measured, n is the number of points being measured.
9. Vrms-1: the root mean square value of a single period of waveform on the
screen or in the gating area.