Setting Of The General Temperature Range - oventrop R-Tronic RT B Installation And Operating Instructions Manual

Table of Contents

Advertisement

"R-Tronic" + "R-Con"

5.2.1 Setting of the general temperature range

The submenu TEMPERATURES offers the option to define a general tempera-
ture range for all heating and setback periods and their respective cycles. The
"R-Tronic" is preset at works to a maximum range between 6 °C and 35 °C.
You can change these values via the function TEMPERATURES X LIMITATION
MIN/MAX.
The new temperature limits are set as follows:
1.
You are in the submenu TEMPERATURES. Turn the Menu-button to the
right until LIMITATION MIN/MAX will be displayed and confirm the
selection by pressing the button.
2.
Define the new lower temperature limit (MIN) and confirm your entry by
pressing the Menu-button.
The message SAVED will be displayed shortly and the display will return
to the selection menu MIN SETTING.
3.
To define the upper temperature limit, turn the Menu-button slightly to
the right and confirm the selection MAX. Enter the new value as
described before.
The new general temperature Iimits of the "R-Tronic" set now.
X
The menu TEMPERATURE UNIT allows switching between degrees Celsius
and Fahrenheit.
NOTE
Please observe that the programmed individual profiles will be influenced by
the new general temperature limits. Should the individual profile settings lie
outside the new defined temperature range, they will automatically be set
to the new limits.
Example: A setback temperature of 12 °C was programmed for a cellar in
the individual profile. The lower temperature range (for this room) was sub-
sequently increased to 14 °C. The setback temperature of your individual
profile will automatically be increased to 14 °C and the room temperature
will not drop below this value.