"R-Tronic" + "R-Con"
5.4.6 Combined control of underfloor heating circuit and radiator
For rooms in which one or several underfloor heating circuit(s) and a radiator
were installed (for instance bathrooms), the "R-Tronic" offers the option of a
combined balance control which serves to compensate the different response
behaviours (a radiator warms up faster) and to co-ordinate the heating effect
relationship of both types of heating.
The "R-Tronic" menu offers the option to specify whether the set nominal val-
ue shall rather be reached via the heat output of the radiator or via the heat
output of the underfloor heating circuit.
B
Prerequisite is that an actuator for wireless thermostats "Aktor MH/MD CON B"
(B) (item no. 1150665/1150675) as well as a control module channel of the wire-
less receiver (C) have been adapted to the "R-Tronic" (A) before. The "Aktor MH/
MD CON B" serves the control of the radiator valve and the actuator(s) "Aktor
T 2P" (D) which is activated via the "R-Con" channel serves the control of the
underfloor heating circuit (see illustration 69).
To specify the heating effect relationship between the surface heating and
the radiator, go the "R-Tronic" menu SETTINGS X CONTROL X OFFSET
BALANCE and determine a value.
Turn the Menu-button of the "R-Tronic" to the left to shift the heat
output towards the radiator.
Turn the Menu-button of the "R-Tronic" to the right to shift the heat
output towards the underfloor heating circuit.
Operation & menu structure
A
(Illustration 69)
C
D
71