"R-Tronic" + "R-Con"
4.3
Wall attachment of the fixing plate with
flush-mounted power pack ("RTFC K")
DANGER
Risk of electric shock!
As the flush-mounted power pack has to be connected to the current
supply of the house, there could be a risk of an electric shock.
 Installation of the flush-mounted power pack must only be carried
out by a qualified electrician.
CAUTION
Risk of fire due to overcharging of the batteries!
There is a risk of overcharging the batteries if the "R-Tronic" is
equipped with batteries and is connected to the 230 V network via
the flush-mounted power pack (types "RT B" and "RTF B").
 The wireless thermostat must never be equipped with batteries
when using the flush-mounted power pack.
1.
Switch off the current supply before installation of the flush-mounted
power pack.
2.
Assemble the electrical connection between the flush-mounted power
pack and the 230 V connection in the flush socket.
3.
Screw the fixing plate to the flush socket and switch on the current supply.
4.
Insert the "R-Tronic" into the fixing plate from the top.
Fixing plate
2
Secondary cable
The flush-mounted power pack has to be installed so
that the primary cables (1) and the secondary cable (2)
do not touch each other. If necessary, these cables are
to be fixed, for instance with a cable retainer in order to
guarantee the physical separation.
The "R-Tronic" is now ready for the "teach in" process (see paragraph 4.6).
X
Flush-mounted
power pack
1
Primary cables 230 V
Installation & initial operation
"R-Tronic RTFC K" (remove batteries
Flush socket
(Illustration 9)
of "RT B"/"RTF B"!)
21