Installation & initial operation
The newly installed module C is not yet ready to operate after connection
of the wireless receiver to the 230 V network (see paragraph 4.5.6). It first has
to be detected by the wireless receiver.
1.
Starting from its normal position (radio symbol), turn the rotary switch of
the wireless module counter clockwise to "Config"
(LED flashes constantly).
Turn the lower rotary switch of the new control module "T 2P" (C)
2.
clockwise until stop. Detection of the new module is indicated by a short
green flashing of the LED of the wireless module.
If further modules have been added to the wireless receiver before, step
2 has to be repeated at each new module.
Finally, turn the lower rotary switch back to RUN.
3.
Set the switch of the wireless module back to its normal position
(radio symbol/RUN) by turning it clockwise.
The new control module was put into operation successfully.
X
NOTE
The rotary switch of the wireless
modules has to be set back to its
normal position after each reconfigu-
ration (step 3).
The wireless receiver is only ready to
operate if the rotary switch is set to
the radio symbol.
32