SELF-DIAGNOSTIC FUNCTION AND DIAGNOSTIC CODE TABLE
EAS20163
SELF-DIAGNOSTIC FUNCTION AND DIAGNOSTIC CODE TABLE (SCU) (for
YZF-R1M)
TIP
If there is a malfunction in the electronically adjustable suspension system, the engine trouble and sys-
tem warning light "1" will come on, and a fault code number "2" will be displayed.
EAS30963
SELF-DIAGNOSTIC FUNCTION TABLE
TIP
For details of the fault code, refer to "TROUBLESHOOTING METHOD (SCU)" on page 8-155.
Fault
code No.
7
Abnormal ABS
9
Abnormal CAN communication (between ECU and SCU)
10
Abnormal CAN communication (between ABS ECU and SCU)
42
Abnormal rear wheel sensor
44
Abnormal SCU EEPROM
46
Abnormal SCU power supply voltage
50
Abnormality inside SCU
Steering damper stepping motor (manufactured by Öhlins: optional): open circuit or short-cir-
66
cuit detected.
89
(or "Err" is
Abnormal CAN communication (between meter assembly and SCU)
displayed)
93
Stepping motor: open or short circuit detected.
98
Abnormal IMU
99
Abnormal CAN communication (between IMU and SCU)
ERS icon
Zero point adjustment of damping force adjustment system was not performed.
blinks
EAS31059
DIAGNOSTIC CODE TABLE
Diagnostic
code No.
09
Monitor voltage
50
1000 r/min
×
0
ODO
km
--.-
FUEL CON
L
A
4
MODE -
PWR
Item
Displays the SCU power
supply voltage.
Approximately 12.0 V
9-12
(SCU) (for YZF-R1M)
17
12 : 00
N
km/h
1
 2
2
2
TCS
SCS
Item
Indicated
2
1
Procedure
Check the displayed SCU
power supply voltage.

Advertisement