10 Data Fields

10.2 Machine data

10.2
Machine data
10.2.1 NC machine data
General values
Number of tool offset parameters
13
(P fields) and thus width of the TO memory
Sign
Input limits
1 to 16
+
As a standard, the TO memory is configured with a width of eleven P fields (P0 to P10). If the
user requires more than eleven tool offset parameters, the TO memory can be expanded to a
maximum of 32 P fields.
Any modifications of the NC machine data become valid only after
formatting the user memory in the installation mode.
Modifications of the NC machine data for tool management are accepted by the TO memory
management only if all D numbers of all configured TO areas are unassigned otherwise,
PLC STOP with error message "Configuring of memory management not possible".
210
Sign
Input limits
1 to 16
+
As a standard, the entire TO memory is configured as one TO area. Splitting up into 16
areas is possible but not supported by package 1.
_______
1)
In the case of SINUMERIK 880/880 GA2, the value 16 applies.
2)
In the case of SINUMERIK 840/840C, the value 32 applies; the value 16 applies if tool management is used.
10–10
Default value
2)
Number of TO areas
Default value
1)
© Siemens AG 1991 All Rights Reserved
Units
10
-
Units
1
-
6FC5 197-0AA40-1BP1
SINUMERIK 840/880 (PJ)
11.92
13
Steps
210
Steps
1)
TO