Siemens SINUMERIK 840 Planning Manual page 131

Function blocks for plc 135 wb
Hide thumbs Also See for SINUMERIK 840:
Table of Contents

Advertisement

5 Configuring
5.15 FB 156 Tool life monitoring/prewarning limit
K =
0:
K < 10:
K = 10:
K > 10:
K > 99:
AKT
Block is active
"1"-signal:
"0"-signal:
Important: A new initiation signal (positive-going edge of "BEAR") is recognized only
if AKT=0.
ZEAB
Tool life elapsed
"1"-signal:
"0"-signal:
F
Error
The error output is set for one cycle. The error number is entered in DB 134, DL 0.
Important: If the block is called several times in a PLC cycle (different job numbers),
the error word entered in DB 134/-DL must be saved immediately after the block call
with the error output set!
F-NR
Error number
The error number is entered in DB 134, DL 0.
Program example:
The default values for tool life and prewarning limit are stored in the NC in the P memories
P10 and P11. The tool data are entered in the magazine table of magazine 2, location 10. The
tool life is measured in minutes (K=10). If the prewarning limit is to be evaluated or the tool to
be disabled immediately, the inputs "VWG" (I 3.1) and/or "SPER" (I 3.2) must be connected
correspondingly. If input I 3.0 (machining active) has a "high" signal, the tool life is counted
down. The part program runs in NC channel 1.
: L
KY 2,10
: T
FW 100
: L
KB 10
: T
FY 103
:
: JU
FB 156
NAME
: STAZ/VWG
BEAR
: I
3.0
VWG
: I
3.1
SPER
: I
3.2
A-NR
: KF+1
MANR
: FY 100
PLSP
: FY 101
NSBY
: DL 17
SPNR
: KF+10
K
: FY 103
AKT
: Q
3.0
ZEAB
: Q
3.1
F
: Q
3.2
:
: BE
5–70
Processing of block aborted. The current values are stored and
the error output set.
Acceleration of tool life down-counting
Tool life down-counting in minutes
Deceleration of tool life down-counting
Processing of block is aborted. The current values are stored and
the error output set.
Block is active
Block is not active
The tool life has elapsed (Tool life <= 0)
The tool life has not yet elapsed
MAGAZINE 2, LOCATION 10
K=10, MINUTE INTERVALS
TOOL LIFE MONITOR
© Siemens AG 1991 All Rights Reserved
01.91
6FC5 197-0AA40-1BP1
SINUMERIK 840/880 (PJ)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840cSinumerik 880Sinumerik 880 ga2

Table of Contents