Siemens SINUMERIK 840 Planning Manual page 125

Function blocks for plc 135 wb
Hide thumbs Also See for SINUMERIK 840:
Table of Contents

Advertisement

5 Configuring
5.14 FB 155 Input via tape
Data structure
Address key
DW 1
DW 2
DW 3
DW 4
DW 5
DW 6
DW 7
DW 8
DW 9
DW 10
Address key
5–64
Data structure of the DB 135
DL
Control word
Unassigned
Control byte
Channel number (parameter)
DB number, channel
DW No. M funct.
Initiation bit M function
DB No. dyn. buffer
Unassigned
Unassigned
Error No. data distributor
Control work DB 135, DW 1
15 14 13 12 11 10
9 8 7 6 5 4 3 2 1 0
© Siemens AG 1991 All Rights Reserved
Comment
DR
DB 135
D 2.8 Enable
loading via tape
Comment
Release tool
Initiate release of tool
Init. 880 tool m. SST DB
Setup progr. monitor.
Program end
Reset
Initiate error message
Do not delete location
Error
Initiate (M function)
Read setup program
Assign
Transfer data
Re-initiate (M function)
Dyn. buffer assigned
Last cutting edge
6FC5 197-0AA40-1BP1
SINUMERIK 840/880 (PJ)
01.91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840cSinumerik 880Sinumerik 880 ga2

Table of Contents