9 Examples
9.2.23 FB 185 Acknowledge manual loading/unloading
Block data
Lib. No.
FBs to be loaded
DBs to be loaded
Type of FB call
DBs to be input
Error messages
Block call FB 185
DB 145
DW 50
Signal descriptions
ZW
Internal statuses
FEHL
Error word: The error number is stored in the form of the interactive text numbers
listed above.
Block structure
9–118
: 10050
: FB 128, FB 130, FB 131, FB 132 FB 152
: None
: Conditional in FB 160
: None
: 05: Acknowledge loading illegal
06: Acknowledge unloading illegal
09: Error TO memory management
11: Loading point: No empty location
12: Error data transfer loading
(detailed error number in DB150,
DW 224; cf. Section 5, FB 128)
13: No unassigned D number available
20: Invalid tool at unloading point
FB Q-MANUEL
ZW
FEHL
DB 40, DW 50
Network 1
* * * * * * * * * *
–
Load or preset status word
–
Save operator panel flags
Network 2
* * * * * * * * * *
–
Initial run routine
–
Determine whether processing with or
without configuring
–
Determine number of 1st reference DB
© Siemens AG 1991 All Rights Reserved
11.92
6FC5 197-0AA40-1BP1
SINUMERIK 840/880 (PJ)