Reseat the faulty power supply by removing and reinstalling it.
NOTE:
After installing a power supply, allow several seconds for the system to recognize the power supply and to determine if it
is working properly.
If the problem persists, see

Troubleshooting cooling problems

CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Ensure that none of the following conditions exist:
System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
A cooling fan is removed or has failed.
The expansion card installation guidelines have not been followed.

Troubleshooting cooling fans

CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
1
Open the system.
2
Reseat the fan or the fan's power cable.
3
If the fan functions properly, close the system.
If the problem persists, see

Troubleshooting system memory

CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
1
If the system is operational, run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.
If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.
2
If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at
least 10 seconds and then reconnect the system to power.
3
Turn on the system and attached peripherals and note the messages on the screen.
If an error message is displayed indicating a fault with a specific memory module, go to step 12.
4
Enter the System Setup and check the system memory setting. Make any changes to the memory settings, if needed.
If the memory settings match the installed memory but a problem is still indicated, go to step 12.
5
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6
Open the system.
7
Check the memory channels and ensure that they are populated correctly.
8
Reseat the memory modules in their sockets.
100
Troubleshooting your system
Getting
Help.
Getting
help.