Error Code
Message Information
PSU0037
Message
LCD Message
Action
PSU0076
Message
LCD Message
Details
Action
PSU1201
Message
Details
Action
PSU1204
Message
LCD Message
Details
Action
PWR1004
Message
Details
Action
PWR1005
Message
Details
Action
PWR1006
Message
LCD Message
Details
Action
126
System messages
Fan failure detected on power supply <number>.
Fan failure detected on PSU <number>. Check PSU.
Check for fan blockage. If the problem persists, see
A power supply wattage mismatch is detected; power supply <number> is rated for
<value> watts.
PSU wattage mismatch; PSU <number> = <value >watts
Power supplies should be of the same input type and power rating.
Install matched power supplies and review this manual for proper configuration.
Power supply redundancy is lost.
The power supply tries to operate in a degraded state. System Performance and power
redundancy may be degraded or lost.
Check input power. Reinstall the power supply. If the issue persists, see
The power supplies are not redundant. Insufficient resources to maintain normal
operations.
PSU redundancy degraded. Check PSU cables.
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
Check the event log for power supply failures. Review system configuration and power
consumption.
The system performance degraded because power capacity has changed.
The system may power down or operate in a performance degraded state.
Check the event log for power supply failures. Review system configuration and power
consumption and upgrade or install power supplies accordingly.
The system performance degraded because the user-defined power capacity has
changed.
The user-defined power settings have affected system operation.
If unintended, review system configuration changes and power policy.
The system halted because system power exceeds capacity.
System power demand exceeds capacity. System halted.
The system halted because system power exceeds capacity.
Review system configuration, upgrade power supplies or reduce system power
consumption.