Table 2-2 PT-PS/PT-PS-DC Electrical Specifications
Item
Input voltage
Input frequency
Power factor correction > 97% efficient, active, meets
Inrush current
Power supply efficiency  75% at full load
* †
Output voltages
Output currents
Output power
Line regulation
Note: The Platinum frame is configured at the factory to operate either from an AC input
voltage or a DC input voltage, but not both. This configuration is based on a
customer's order and cannot be changed once the frame leaves the factory. The
AC and DC power supply modules are mechanically compatible with all Platinum frames
and are similar in appearance, so you can easily install the wrong power supply module into
a Platinum frame. For your safety, the configurations of both the AC input voltage and DC
input voltage Platinum frames are such that, if the wrong power supply module is installed,
no electrical fault will occur, no circuit breakers will trip, and the power supply module will
not attempt to power up and will not be damaged. Most important, you will not be in any
danger. If you find that either an AC or a DC power supply module will not power up in a
Platinum frame that has been connected to the power mains of a facility, you should first
confirm the correct power supply module was installed. Platinum frames configured to use
100-240 VAC require the AC power supply module; Platinum frames configured to use -40
to -60 VDC require the DC power supply module.
All power supplies are installed at our manufacturing facility. See
Supplies
on page 377 for the procedure for field expansion of power supplies. If you need
to purchase additional components, please contact your dealer or our Sales Department.
This module requires no specialized configuration procedures.
Specifications and designs are subject to change without notice.
Specification
PT-PS
Universal AC input (100 VAC to 240 VAC)
47 – 63 Hz
EN61000-3-2 as a Class A device when
under 50% load
 35 Amps peak at 264 VAC
V1 = 5 VDC
V2 = 24 VDC
V3 = 24 VDC
5 VDC @ 10 amps
24 VDC @ 15 amps
24 VDC @ 15 amps
750 watts (continuous)
< ± 0.1%
Installing Power
PT-PS-DC
-40 VDC to -60 VDC
 35 Amps peak at -72 VDC
 75% at full load
V1 = 5 VDC
V2 = 24 VDC
V3 = 24 VDC
5 VDC @ 10 amps
24 VDC @ 15 amps
24 VDC @ 15 amps
750 watts (continuous)
< ± 0.1%