Imagine communications Platinum PM-FR-5 Installation And Operation Manual page 423

Frame and modules
Table of Contents

Advertisement

Table 8-4 Application Parameters Available Through Configuration Utility Software (Continued)
(* denotes default setting; [RO] = Read-only parameter)
Parameter
Sync Reference1
Sync Reference4
Detected Reference1 [RO]
Detected Reference4 [RO]
Description
Only used if sync mode is
"Standard" (see the software
application manual for a description
of this setting)
Sync reference that is automatically
detected by PT-RES (this is the sync
reference used when Sync Mode
parameter is set to Auto)
Four concurrent available sync
references are allowed
If an external sync reference is
removed from the frame, the Sync
Presence parameter will indicate
that it is not present; however, the
Detected Reference parameter will
continue to show the previous
detected reference to prevent
interruption in switching operations
Platinum Frames and Modules
Installation, Configuration, and Operation Manual
Options
None*
1280×720/50P Line 7
1280×720/60P Line 7
1280×720/60P/1.001 Line 7
1920×1080/24P Line 7
1920×1080/24P/1.001 Line 7
1920×1080/24PsF Line 7
1920×1080/24PsF/1.001 Line 7
1920×1080/25P Line 7
1920×1080/30P Line 7
1920×1080/30P/1.001 Line 7
1920×1080/50I Line 7
1920×1080/60I Line 7
1920×1080/60I/1.001 Line 7
Analog 525/60 Line 10
Analog 525/60/1.001 Line 10
Analog 625/50 Line 6
None*
1280×720/50P Line 7
1280×720/60P Line 7
1280×720/60P/1.001 Line 7
1920×1080/24P Line 7
1920×1080/24P/1.001 Line 7
1920×1080/24PsF Line 7
1920×1080/24PsF/1.001 Line 7
1920×1080/25P Line 7
1920×1080/30P Line 7
1920×1080/30P/1.001 Line 7
1920×1080/50I Line 7
1920×1080/60I Line 7
1920×1080/60I/1.001 Line 7
Analog 525/60 Line 10
Analog 525/60/1.001 Line 10
Analog 625/50 Line 6
395