238
Chapter 4
Output Modules

Controllable Parameters

Table 4-16 PM-SR-OB+/PT-SR-OB+ User-Controllable Parameters List
[RO] = Read-only parameter
Parameter
Lock Detect (1-8) [RO]
Mute_ (1-8)
Reclocker Mode (1-8)
Auto Bypass (1-8)
Bypass (1-8)
Input EQ (1-8)
Output Mode (1-8)
Data Rate (1-8)
Board Level Hysteresis
Sync Type
Module ID
Table 4-16
lists the user-controllable parameters for the PM-SR-OB+ and PT-SR-OB+
modules. These parameters are accessible via either RouterMapper or CCS Navigator. In
RouterMapper, parameters are found in the Configure Module Parameters and/or Module
Parameters list boxes. In Navigator, when in control mode, double-click on the device name
to open a window that displays that device's parameter list.
See the appropriate reference manual for information on how to set these parameters.
Description
Reports if data is re-locked by
reclocking stage
Sets mute for any data passing
reclocking stage
Sets the reclock mode to manual or
automatic
Enables or disables the reclock
automatic bypass function
Sets bypass for ignoring reclocking
function
Sets input EQ setting for onboard
switchers
Determines if output signal comes
from the main module or
submodule (if installed)
Sets the reclock rate
Sets hysteresis for parameters
needing it
Selects which physical sync port the
module uses as a reference
Displays unique module identifier of
PM-SR-OB+ or PT-SR-OB+ module
Options
Not locked
Locked
Muted
Unmuted
Manual
Auto
Off
On
Off
On
12 dB
5 dB
Main module
Submodule
270 Mb/s
0 to 5 seconds in 500 ns steps
Sync1
Sync2
Sync3
Sync4
String