Table 3-35 PM-ADCT-IB/PT-ADCT-IB User-Controllable Parameters List (Continued)
[RO] = Read-only parameter
Parameter
Operating Mode
Internal Mode Sampling Frequency
Select
Internal Mode Sampling Frequency
Adjust
External Reference Frequency [RO]
Audio Reference
Board Level Hysteresis
Ch. A Presence (1-16)
Ch. B Presence (1-16)
Ext. Reference Lock Error
Ext. Reference CRC Error
Ext. Reference Validity Error
Ext. Reference Confidence Error
Ext. Reference Parity Error
Description
Sets PM-ADCT-IB/PT-ADCT-IB
operating mode
Sets the sampling frequency when
in internal mode
Adjusts internal mode sampling
frequency
Reports external reference
frequency
(NOTE: Must be a sample rate
supported by TDM)
Selects AES reference input for
source
Sets hysteresis for parameters
needing it
Reports absence or presence of a
signal on Channel A
Reports absence or presence of a
signal on Channel B
Reports lock error on external
reference
Reports CRC error on external
reference
Reports validity error on external
reference
Reports confidence error on
external reference
Reports parity error on external
reference
Options
Auto mode
Internal mode
External mode
32 kHz
44.1 kHz
48 kHz
88.2 kHz
96k Hz
192 kHz
0x00 to 0xFF
Unlocked
Out of Range
192 kHz
96 kHz
88.2 kHz
48 kHz
44.1 kHz
32 kHz
Sync 4
Sync 3
Sync 2
Sync 1
0 to 5 seconds in 500 ns steps
Absent
Present
Absent
Present
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes