Imagine communications Platinum PM-FR-5 Installation And Operation Manual page 468

Frame and modules
Table of Contents

Advertisement

440
Chapter 9
Output Monitoring Modules
Table 9-5 PT-HSRAEC-OM Parameters List (Continued)
[RO] = Read-only parameter
Parameters
Index Light Mode
Board Level Hysteresis
Mute
Video Output Rate
Green Mode
External Video Presence [RO]
EQ Bypass
Lock Detect [RO]
Reclocker Mode
Locked Data Rate [RO]
Reclocker Bypass
Description
BNC light source (LED) control
In Auto mode, the LED of the
Video Input BNC turns on if no
cable is applied, so that you can
find the BNC easily; it turns off to
save power if signal applied
In Auto mode, the LED of the
Video Output BNC turns on if
output is enabled; it turns off if
output is muted
Sets hysteresis for parameters
needing it
Mutes specified output channel
Video cable driver slew rate select
When Reclocker Bypass is set to
No and input is locked, the video
output rate is automatically
determined by software based on
input rate.
When input is not locked, or
Reclocker Bypass is set to Yes,
this parameter can be used to set
the preferred output slew rate
Enables or disables power-saving
feature
Reports presence or absence of
valid signal
Enables or disables bypass cable
equalization
Reports if data is relocked by
reclocking stage
Sets the reclock mode to automatic
or to one of three manual fixed
rates
Detects data rate
Enforces reclocking bypass function
Options
Off
On
Auto
0 to 5 seconds in 500 ns steps
Mute on
Mute off
SD (700ps)
HD (100ps)
Disabled
Enabled
Signal absent
Signal present
Disabled
Enabled
Not locked
Locked
1.48 Gb/s
2.97 Gb/s
270 Mb/s
Auto
1.48 Gb/s
2.97 Gb/s
270 Mb/s
Auto
Auto bypass
Enforced bypass

Advertisement

Table of Contents
loading

This manual is also suitable for:

Platinum pt-fr-28Platinum pt-fr-15Platinum pm-fr-9

Table of Contents