404
Chapter 8
Configuration
Figure 8-6 Step 3: Sync 1 Switch Configuration to Auto Mode
4
Configure Sync 2 switch configuration to Advanced, and then enter the sync pulse delay, as
shown in
Figure
8-7.
Note: See
Table
8-5,
The example presumes selection of an Analog 525 reference with 1920×1080i/60 signals,
which has a video time delay value of 164.
Figure 8-7 Step 4: Sync 2 Switch Configuration to Advanced Mode
5
Switch to the Platinum Configured Matrices tab, and then configure each HD output
module to use Sync 2 for proper switch point timing.
Table
8-6, and
Table 8-7
for standard video timing delay values.