Configuration
Table 8-4 Application Parameters Available Through Configuration Utility Software (Continued)
(* denotes default setting; [RO] = Read-only parameter)
Parameter
Redundancy Mode
Redundant Switch Mode
External Temperature [RO]
General Alarm1 [RO]
General Alarm3 [RO]
Alarm Enable1
Alarm Enable3
Active Crosspoint1
Active Crosspoint8
Sync Enable1
Sync Enable4
Description
Instructs PT-RES to automatically
switch crosspoints from a crosspoint
module to its redundant crosspoint
module when the active one is
removed.
This feature is not available for
frames that do not have redundant
crosspoint modules; when set to
Manual, you must switch each
crosspoint to the redundant card by
setting it to Active by using the
crosspoint active parameter
Instructs PT-RES to switch all
currently active crosspoints to the
redundant crosspoint module when
the active one is removed.
Specifies external operating
temperature in degrees Celsius
Alarm relay on PT-RES
Enables/disables General Alarm
parameter
For frames that support redundant
crosspoints, this parameter allows
you to set the currently active
crosspoint module
If Redundant Switch Mode is set to
Switch All" all active crosspoints will
switch through the set crosspoint
module and the corresponding,
previous active crosspoint module
will become inactive
For all frames the value of this
parameter indicates whether the
crosspoint module installed is active
(present and allowing switched)
Allows you to select which sync
references can trigger crosspoint
switches
Options
Manual
Auto
Switch All
–128° to 120°C
No Alarm
Alarm
Enable
Disable
On
Off
On
Off