Diagnosing Via The Cpx−Fec Or Cpx Field Bus Node - Festo CPX Series Electronic Manual

Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

4. Diagnosis and error treatment
4.4
Diagnosing via the CPX−FEC or CPX field bus node
4.4.1 Status bits of the CPX terminal
Bit
Diagnostic information
with 1−signal
0
Fault at valve
1
Fault at output
2
Fault at input
3
Fault at analogue
module/technology
module (function module)
4
Undervoltage
5
Short circuit/overload
6
Wire fracture
7
Other faults
1)
See Tab. 4/2
Tab. 4/7:
Overview of status bits
4−14
Faults of the CPX−CP interface or the CP module connected
are reported to the CPX field bus node or CPX−FEC as CPX
fault messages. The following sections contain the special
features of the representation for the CPX−specific diagnostic
options.
Status bits (see section 4.4.1)
Diagnostic memory (I/O diagnostic interface,
see section 4.4.2)
Tab. 4/7 shows the effect of the CPX−CP interface on the
CPX terminal's status bits.
Description
Module type on
which a fault has
which a fault has
occurred
occurred
Type of fault
Type of fault
Further instructions on the function and content of the status
bits can be found in the CPX system manual.
Cause of the fault, CPX−CP interface
Bit 3 is set for all faults of the CPX−CP
interface.
1)
Fault number 5
1)
Fault number 2
Fault number 34, 35, 36
Festo P.BE−CPX−CP−E N en 0405NH