1. Installation
1.2

Setting the CPX field bus node

1.2.1 Removing and fitting the cover over the DIL switches

Removing
Assembly
1−6
In order to set the CPX field bus node, you must first remove
the cover over the DIL switches.
Caution
The CPX field bus node contains electrostatically sensitive
components.
Do not therefore touch any contacts.
·
Observe the regulations for handling electrostatically
·
sensitive components.
You will then prevent the electronics in the node from being
damaged.
1. Switch off the power supply.
2. Unscrew the two fastening screws in the switch cover.
3. Lift up the cover.
1. Place the cover carefully on the node.
Please note
Make sure that the seal is seated correctly.
2. Tighten both fastening screws at first by hand and then
with torque 0.5 ... 0.8 Nm.
Festo P.BE−CPX−FB11−EN en 0503b