3. Commissioning
Module parameters: Monitoring of CPX module CP modules
Function no.
4828 + m * 64 + x;
x = depends on string no. and module no. of the CP module, see Tab. 3/7
Description
Monitoring of the possible faults can be activated or deactivated (suppressed)
for CP each module independently. Active monitoring causes the following:
The fault is:
Monitoring
Bit
Description
0
Power failure/undervoltage for:
Short circuit/overload on:
1
Values
1 = active (presetting)
0 = inactive
Note
Monitoring can also be set for the complete CPX terminal
(see Monitoring system parameters").
Tab. 3/8:
Monitoring of CPX module CP modules
Festo P.BE−CPX−CP−EN en 0405NH
sent to the CPX field bus node
shown on the module common fault LED.
CP input modules (Vsen): Power failure (or short
circuit) of the sensor supply for modules with an
additional supply
CP output modules (Vout): Power failure of the
load supply for modules with an additional supply
CP valve terminals (Vval): Power failure of the
load supply of the valves
CP output modules Output
m = module number (0 ... 47)
[Monitor ...]
[Monitor Vsen/Vout/Vval]
[Monitor SC]
[Active]
[Inactive]
3−21