1. System summary of the CP system
1
Field bus (incoming)
2
Field bus (continuing)
3
CP master
(CPX−CP interface)
4
CP string
5
CP input module
6
CP valve terminal
7
Sensor
8
Cylinder
9
CP output module
Fig. 1/2: Method of operation of the CP system
Cable lengths
Festo P.BE−CPX−CP−E N en 0405NH
In the capacity of CP master, each CPX−CP interface controls
data transfer to a wide variety of controller systems in a CPX
terminal. In principle, multiple CPX−CP interfaces can be used
in a CPX terminal.
1
2
I/O data exchange constantly takes place via the CPX−CP
interface between the CPX terminal and the CP modules
connected to the CPX−CP interface.
The complete length of cable in a string must not exceed
10 m.
3
4
5
6
7
8
9