4. Diagnosis and error treatment
Fault
Description
number
Module code not permitted or incorrect
16
module
(Handheld: [Module code incorrect] )
The saved string assignment of the
CPX−CP interface does not correspond to
the configuration saved in the CPX field
bus node or the CPX−FEC.
Tab. 4/3:
Additional fault message of the CPX terminal
CP module type
Fault number
CPV..−GE−FB−...
CPA..−...
CP−E16−M8
CP−E16N−M8
CP−E16−M8−Z
CP−E16−12−5−POL
CP−E16N−M12
CP−E16−KL−IP20
CP−E08−M12−CL
CP−E08−M8−CL
CP−E08−KL−CL
CP−A08−M12−5−POL
CP−A08N−M12
CP−A04−M12−CL
Tab. 4/4:
CP module−related fault assignment
Festo P.BE−CPX−CP−E N en 0405NH
Specific monitoring of the CPX−CP interface can be activated
or deactivated by means of parameterisation.
Parameterisation of the CPX−CP interface affects only certain
CP modules. Tab. 4/4 shows an overview (updated March
2004).
Monitoring
Undervoltage/short
circuit in sensor supply
Vsen
5
x
x
x
x
x
x
Fault treatment
For the CPX field bus node:
·
Change parameter System start..." to
... Default parameterisation and
current CPX equipment status"
For the CPX−FEC:
·
Save the actual configuration as the set
configuration using the FST software
Short circuit/
Undervoltage in
overload
actuator supply
SCO/SCS
Vout
2
5
x
x
x
x
x
x
x
x
x
Undervoltage in
valve supply
Vval
5
x
x
4−7