B. CPX−CP interface with Interbus field bus node
CPX−CP interface
Diag. module
Fig. B/5: Diagnostic channel assignment of a CP system (Interbus), example 2
B−8
String
Module 0
8 I
L1
Module 0
[L1/M0]
I byte 0
Diag. I channel 0
16 O
L2
Module 4
[L2/M0]
O byte 3
O byte 4
Diag. O channel 3
Diag. O channel 4
L3
16 O
Module 8
[L3/M0]
O byte 5
O byte 6
Diag. O channel 5
Diag. O channel 6
L4
8 O
Module 12
[L4/M0]
O byte 9
Diag. O channel 9
Module 1
Module 2
8 O
8 O
Module 1
Module 2
[L1/M1]
[L1/M2]
O byte 0
O byte 1
Diag. O channel 0
Diag. O channel 1
16 I
(Module 6)
Module 5
[L2/M1]
I byte 1
I byte 2
Diag. I channel 1
Diag. I channel 2
8 I
16 O
Module 9
Module 10
[L3/M1]
[L3/M2]
I byte 3
O byte 7
O byte 8
Diag. I channel 3
Diag. O channel 7
Diag. O channel 8
8 O
8 O
Module 13
Module 14
[L4/M1]
[L4/M2]
O byte 10
O byte 11
Diag. O channel 10
Diag. O channel 11
Module 3
8 O
Module 3
[L1/M3]
O byte 2
Diag. O channel 2
(Module 7)
16 I
Module 11
[L3/M3]
I byte 4
I byte 5
Diag. I channel 4
Diag. I channel 5
8 O
Module 15
[L4/M3]
O byte 12
Diag. O channel 12