10
Maintenance and care
Warning
Compressed air tubing or attachments are set free under pressure. Movable parts move
uncontrollably.
Injury (death) due to impact or pinching.
Switch off the compressed air supply prior to mounting work.
Support movable pneumatic components, if needed.
Vent all pneumatic components completely, e.g. through appropriate components,
such as non-return valves, service unit.
10.2
Cleaning
Use non-abrasive cleaning agents.
Clean the handling system as required with a soft cloth.
10.3
Lubrication
The handling system is lubricated initially.
Note
Trouble-free operation and a long service life require regular relubrication.
Lubricate axes properly.
Observe specifications for lubrication.
Use appropriate grease gun. Accessories (è www.festo.com/catalogue).
Requirements
Lubrication interval
Lubricating grease
Amount of lubricant
Festo – GDCP-YXC-EN – 1502NH – English
[km]
2500
See documentation for the axes (è www.festo.com/sp)
See documentation for the axes (è www.festo.com/sp)
87